Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 301
Filtrar
1.
J Hazard Mater ; 470: 134173, 2024 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-38603906

RESUMEN

Potentially hazardous particles from paints and functional coatings are an overlooked fraction of microplastic (MP) pollution since their accurate identification and quantification in environmental samples remains difficult. We have applied the most relevant techniques from the field of microplastic analysis for their suitability to chemically characterize anti-corrosion coatings containing a variety of polymer binders (LDIR, Raman and FTIR spectroscopy, Py-GC/MS) and inorganic additives (ICP-MS/MS). We present the basis of a possible toolbox to study the release and fate of coating particles in the (marine) environment. Our results indicate that, due to material properties, spectroscopic methods alone appear to be unsuitable for quantification of coating/paint particles and underestimate their environmental abundance. ICP-MS/MS and an optimized Py-GC/MS approach in combination with multivariate statistics enables a straightforward comparison of the multi-elemental and organic additive fingerprints of paint particles. The approach can improve the identification of unknown particles in environmental samples by an assignment to different typically used coating types. In future, this approach may facilitate allocation of emission sources of different environmental paint/coating particles. Indeed, future work will be required to tackle various remaining analytical challenges, such as optimized particle extraction/separation of environmental coating particles.

2.
Environ Pollut ; 302: 119040, 2022 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-35202763

RESUMEN

The North Sea and its coastal zones are heavily impacted by anthropogenic activities, which has resulted in significant chemical pollution ever since the beginning of the industrialization in Europe during the 19th century. In order to assess the chemical Anthropocene, natural archives, such as sediment cores, can serve as a valuable data source to reconstruct historical emission trends and to verify the effectiveness of changing environmental legislation. In this study, we investigated 90 contaminants covering inorganic and organic pollutant groups analyzed in a set of sediment cores taken in the North Seas' main sedimentation area (Skagerrak). We thereby develop a chemical pollution fingerprint that records the constant input of pollutants over time and illustrates their continued great relevance for the present. Additionally, samples were radiometrically dated and PAH and PCB levels in porewater were determined using equilibrium passive sampling. Furthermore, we elucidated the origin of lead (Pb) contamination utilizing non-traditional stable isotopic analysis. Our results reveal three main findings: 1. for all organic contaminant groups covered (PAHs, OCPs, PCBs, PBDEs and PFASs) as well as the elements lead (Pb) and titanium (Ti), determined concentrations decreased towards more recent deposited sediment. These decreasing trends could be linked to the time of introductions of restrictions and bans and therefor our results confirm, amongst possible other factors, the effectiveness of environmental legislation by revealing a successive change in contamination levels over the decades. 2. concentration trends for ΣPAH and ΣPCB measured in porewater correspond well with the ones found in sediment which suggests that this method can be a useful expansion to traditional bulk sediment analysis to determine the biologically available pollutant fraction. 3. Arsenic (As) concentrations were higher in younger sediment layers, potentially caused by emissions of corroded warfare material disposed in the study area after WW II.


Asunto(s)
Bifenilos Policlorados , Contaminantes Químicos del Agua , Monitoreo del Ambiente/métodos , Sedimentos Geológicos , Mar del Norte , Bifenilos Policlorados/análisis , Contaminantes Químicos del Agua/análisis
3.
J Intern Med ; 290(3): 728-739, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-33755279

RESUMEN

BACKGROUND: The diagnosis of cardiac syncope remains a challenge in the emergency department (ED). OBJECTIVE: Assessing the diagnostic accuracy of the early standardized clinical judgement (ESCJ) including a standardized syncope-specific case report form (CRF) in comparison with a recommended multivariable diagnostic score. METHODS: In a prospective international observational multicentre study, diagnostic accuracy for cardiac syncope of ESCJ by the ED physician amongst patients ≥ 40 years presenting with syncope to the ED was directly compared with that of the Evaluation of Guidelines in Syncope Study (EGSYS) diagnostic score. Cardiac syncope was centrally adjudicated independently of the ESCJ or conducted workup by two ED specialists based on all information available up to 1-year follow-up. Secondary aims included direct comparison with high-sensitivity cardiac troponin I (hs-cTnI) and B-type natriuretic peptide (BNP) concentrations and a Lasso regression to identify variables contributing most to ESCJ. RESULTS: Cardiac syncope was adjudicated in 252/1494 patients (15.2%). The diagnostic accuracy of ESCJ for cardiac syncope as quantified by the area under the curve (AUC) was 0.87 (95% CI: 0.84-0.89), and higher compared with the EGSYS diagnostic score (0.73 (95% CI: 0.70-0.76)), hs-cTnI (0.77 (95% CI: 0.73-0.80)) and BNP (0.77 (95% CI: 0.74-0.80)), all P < 0.001. Both biomarkers (alone or in combination) on top of the ESCJ significantly improved diagnostic accuracy. CONCLUSION: ESCJ including a standardized syncope-specific CRF has very high diagnostic accuracy and outperforms the EGSYS score, hs-cTnI and BNP.


Asunto(s)
Razonamiento Clínico , Síncope , Biomarcadores , Diagnóstico Precoz , Servicio de Urgencia en Hospital , Humanos , Péptido Natriurético Encefálico , Estudios Prospectivos , Síncope/diagnóstico , Síncope/etiología , Troponina I
4.
Neurol Res Pract ; 2: 8, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33324914

RESUMEN

INTRODUCTION: Cerebrospinal fluid (CSF) analysis is important for detecting inflammation of the nervous system and the meninges, bleeding in the area of the subarachnoid space that may not be visualized by imaging, and the spread of malignant diseases to the CSF space. In the diagnosis and differential diagnosis of neurodegenerative diseases, the importance of CSF analysis is increasing. Measuring the opening pressure of CSF in idiopathic intracranial hypertension and at spinal tap in normal pressure hydrocephalus constitute diagnostic examination procedures with therapeutic benefits.Recommendations (most important 3-5 recommendations on a glimpse): The indications and contraindications must be checked before lumbar puncture (LP) is performed, and sampling CSF requires the consent of the patient.Puncture with an atraumatic needle is associated with a lower incidence of postpuncture discomfort. The frequency of postpuncture syndrome correlates inversely with age and body mass index, and it is more common in women and patients with a history of headache. The sharp needle is preferably used in older or obese patients, also in punctures expected to be difficult.In order to avoid repeating LP, a sufficient quantity of CSF (at least 10 ml) should be collected. The CSF sample and the serum sample taken at the same time should be sent to a specialized laboratory immediately so that the emergency and basic CSF analysis program can be carried out within 2 h.The indication for LP in anticoagulant therapy should always be decided on an individual basis. The risk of interrupting anticoagulant therapy must be weighed against the increased bleeding risk of LP with anticoagulant therapy.As a quality assurance measure in CSF analysis, it is recommended that all cytological, clinical-chemical, and microbiological findings are combined in an integrated summary report and evaluated by an expert in CSF analysis. CONCLUSIONS: In view of the importance and developments in CSF analysis, the S1 guideline "Lumbar puncture and cerebrospinal fluid analysis" was recently prepared by the German Society for CSF analysis and clinical neurochemistry (DGLN) and published in German in accordance with the guidelines of the AWMF (https://www.awmf.org). /uploads/tx_szleitlinien/030-141l_S1_Lumbalpunktion_und_Liquordiagnostik_2019-08.pdf). The present article is an abridged translation of the above cited guideline. The guideline has been jointly edited by the DGLN and DGN.

6.
Transplant Proc ; 52(3): 926-931, 2020 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-32139278

RESUMEN

BACKGROUND: In past decades, liver transplant (LT) patients were not routinely screened for hepatitis E virus (HEV) infection, and thus it might have been misdiagnosed as an acute rejection episode. Our aim was to analyze a real-world cohort of LT patients who presented with at least 1 episode of biopsy-proven acute rejection (BPAR) and suffered from persistent elevated transaminases, to evaluate the frequency of HEV infection misdiagnosed as a rejection episode. METHODS: Data from 306 patients transplanted between 1997 and 2017, including 565 liver biopsies, were analyzed. Biopsies from patients suffering from hepatitis C (n = 79; 25.8%) and from patients who presented with a Rejection Activity Index <5 (n = 134; 43.8%) were excluded. A subgroup of 74 patients (with 134 BPAR) with persistently elevated liver enzymes was chosen for further HEV testing. RESULTS: Positive HEV IgG was detectable in 18 of 73 patients (24.7%). Positive HEV RNA was diagnosed in 3 of 73 patients with BPAR (4.1%). Patients with HEV infection showed no difference in etiology of the liver disease, type of immunosuppression, or median Rejection Activity Index. CONCLUSION: Few HEV infections were misdiagnosed as acute rejection episodes in this real-world cohort. Thus, HEV infection is an infrequent diagnosis in cases with persistent elevated liver enzymes and BPAR after LT.


Asunto(s)
Rechazo de Injerto/diagnóstico , Hepatitis E/complicaciones , Hepatitis E/diagnóstico , Trasplante de Hígado , Adulto , Estudios de Cohortes , Diagnóstico Diferencial , Femenino , Anticuerpos Antihepatitis/sangre , Humanos , Masculino , Persona de Mediana Edad
7.
Sci Total Environ ; 707: 135219, 2020 Mar 10.
Artículo en Inglés | MEDLINE | ID: mdl-31869611

RESUMEN

Recent studies suggested the use of the isotopic composition of Zn as a possible tracer for anthropogenic Zn emissions. Nevertheless, studies mainly focused on sampling areas of a few km2 with well-characterized anthropogenic Zn emissions. In contrast, this study focused on analyzing a large sample set of water and sediment samples taken throughout the course of the Elbe River, a large, anthropogenically impacted river system located in Central Europe. The primary objective was to evaluate the use of the isotopic composition of Zn to trace anthropogenic Zn emission on a large regional scale. In total 18 water and 26 surface sediment samples were investigated, covering the complete course of over 700 km of the German Elbe between the German/Czech border and the German North Sea, including six tributaries. Stable isotope abundance ratios of Zn were assessed by multi-collector inductively coupled plasma mass spectrometry (MC ICP-MS) in water filtrates (<0.45 µm) and total digests of the sieved surface sediment fraction (<63 µm) after analyte/matrix separation using Bio-Rad AG MP-1 resin via a micro-column approach and application of a 64Zn/67Zn double spike. Measured isotopic compositions of δ66Zn/64ZnIRMM-3702 ranged from -0.10 ‰ to 0.32 ‰ for sediment samples, and from -0.51 ‰ to 0.45 ‰ for water samples. In comparison to historical data some tributaries still feature high mass fractions of anthropogenic Zn (e.g. Mulde, Triebisch) combined with δ66Zn/64ZnIRMM-3702 values higher than the lithogenic background. The dissolved δ66Zn/64ZnIRMM-3702 values showed a potential correlation with pH. Our results indicate that biogeochemical processes like absorption may play a key role in natural Zn isotopic fractionation making it difficult to distinguish between natural and anthropogenic processes.

8.
Mar Environ Res ; 151: 104768, 2019 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-31519451

RESUMEN

The scientific and public interest regarding environmental pollution with microplastic has considerably increased within the last 15 years. Nevertheless, up to now there is no widely applied standard operation procedure for microplastic sampling, resulting in a lack of inter-study comparability. In addition, many studies on microplastic occurrences do not indicate a sound methodological validation of the applied methods and procedures. This study presents an alternative volume-reduced sampling technique to sample the entire load of suspended particulate matter including microplastic particles in natural waters, based on continuous flow centrifugation. For the lab-scale validation of the proposed instrumental setup, six different microplastic types (PE, PET, PS, PVDC, EPS and PP) were used. The particles covered a size range from 1 µm to 1 mm and a density range from 0.94 g mL-1 to 1.63 g mL-1. Recoveries ranged from 95.0% ±â€¯2.3% - 99.1% ±â€¯0.3% for virgin powders and from 96.1% ±â€¯0.6% - 99.4% ±â€¯0.2% (1 SD, n = 2 - 3) for microplastic suspended in river water for 40 days. Gravimetric and microscopic analysis of the effluent indicates efficient removal of microplastic from the suspensions. Static light scattering analysis of the microplastic suspensions prior to and after centrifugation confirmed that no change of the particle size distribution has occurred - neither through aggregation nor through size-discrimination during centrifugation. Moreover, the system was tested in the field and used twice to sample suspended particulate matter from the Elbe estuary directly on site. Based on these first lab-scale experiments, continuous flow centrifugation proves a promising technique bearing potential to alleviate drawbacks such as contamination, filter clogging and particle size-discrimination of commonly used volume-reduced microplastic sampling approaches.


Asunto(s)
Monitoreo del Ambiente/métodos , Microplásticos/análisis , Contaminantes Químicos del Agua , Centrifugación
9.
Clin Res Cardiol Suppl ; 14(Suppl 1): 33-38, 2019 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-30838552

RESUMEN

BACKGROUND: Lipoprotein(a) (Lp(a)) is a genetic risk factor for cardiovascular disease (CVD) and is associated with the induction and sustaining of atherosclerotic cardiovascular diseases (ASCVD). Since 2008 Lp(a) along with progressive CVD has been approved as an indication for regular lipoprotein apheresis (LA) in Germany. The German Lipoprotein Apheresis Registry (GLAR) has been initiated to provide statistical evidence for the assessment of extracorporeal procedures to treat dyslipidemia for both LDL-cholesterol (LDL-C) and Lp(a). The GLAR now allows prospective investigations over a 5-year period about annual incidence rates of cardiovascular events. Here Lp(a) patients (LDL-C < 100 mg/dl; Lp(a) > 60 mg/dl or >120 nmol/l) showed the same reduction of major coronary (83%) and non-coronary events (63%) as had been formerly shown in the Pro(a)LiFe study. However, Lp(a) is not only an apolipoprotein(a) (apo(a)) and LDL-C containing particle, which is covalently bound to a LDL-C core by a disulphide bridge. The composition of this particle, inter alia containing oxidized phospholipids, gives pro-atherosclerotic, pro-inflammatory, and pro-thrombotic properties, inducing atherosclerotic processes mainly in the arterial wall. However, recent investigations have shown that a reduction of inflammatory settings without LDL-C or Lp(a) reduction may reduce ASCVD events. Lipoprotein apheresis (LA) could not only reduce LDL-C and Lp(a) in parallel, but also different inflammatory and coagulation parameters. In summary lipoprotein apheresis is not only anti-atherosclerotic, but also anti-inflammatory and anti-thrombotic and therefore an ideal treatment option with respect to the shown reduction of major adverse coronary events (MACE) and major adverse non-coronary events (MANCE) by reducing Lp(a) levels.


Asunto(s)
Aterosclerosis/sangre , Eliminación de Componentes Sanguíneos/métodos , Enfermedades Cardiovasculares/sangre , Lipoproteína(a)/sangre , Aterosclerosis/genética , Aterosclerosis/terapia , Enfermedades Cardiovasculares/genética , Enfermedades Cardiovasculares/terapia , LDL-Colesterol/sangre , Dislipidemias/terapia , Predisposición Genética a la Enfermedad , Alemania , Humanos , Lipoproteína(a)/genética , Sistema de Registros , Factores de Riesgo
10.
Dent Mater ; 35(5): 709-712, 2019 05.
Artículo en Inglés | MEDLINE | ID: mdl-30846373

RESUMEN

Dental restorations made from alloys corrode during their service time. In cases of suspected toxic or allergic reactions to the corrosion products, the composition of the intraoral dental restorations has to be determined. The sample materials can be obtained intra-orally in a non-destructive manner using the chipping test. Metallic shavings are extracted with the aid of a dental stone and graphite carrier platelet, which is then transferred to an electron microscope for electro dispersive X-ray (EDX) analysis. The chipping test suffers from a rather complicated and error-prone procedure of obtaining and transferring the samples. OBJECTIVE: The objective of the present study was the validation of a simplified method for non-destructive in-situ extraction of dental alloy samples, using a newly developed dental bur made from carbon fiber reinforced polyether ether ketone (PEEK), which at the same time serves as an electrically conductive sample carrier for EDX analysis. METHODS: Fifteen burs for dental hand pieces were manufactured from carbon fiber reinforced PEEK, using two formulations. The burs were passed over precious and non-precious dental alloys with different rotation speeds. The alloy samples embedded in the burs were analyzed using EDX and compared to a control. RESULTS: The burs manufactured from PEEK containing 30% short carbon fibers proved sufficiently robust for sample extraction even from the harder non-precious metals. The results of EDX analysis were in accordance with the control,no statistical significant differences, free of contamination, and were not affected by rotation speed,higher as 20%. SIGNIFICANCE: The proposed method is valid, practical and constitutes an improvement over the traditional chipping test.


Asunto(s)
Aleaciones Dentales , Materiales Dentales , Corrosión , Equipo Dental de Alta Velocidad , Cetonas
11.
BMC Fam Pract ; 19(1): 129, 2018 07 27.
Artículo en Inglés | MEDLINE | ID: mdl-30053834

RESUMEN

BACKGROUND: Medically unexplained symptoms (MUS) and somatoform disorders are common in general practices, but there is evidence that general practitioners (GPs) rarely use these codes. Assuming that correct classification and coding of symptoms and diseases are important for adequate management and treatment, insights into these processes could reveal problematic areas and possible solutions. Our study aims at exploring general practitioners' views on coding and reasons for not coding MUS/somatoform disorders. METHODS: We invited GPs to participate in six focus groups (N = 42). Patient vignettes and a semi-structured guideline were used by two moderators to facilitate the discussions. Recordings were transcribed verbatim. Two researchers analyzed the data using structuring content analysis with deductive and inductive category building. RESULTS: Three main categories turned out to be most relevant. For category a) "benefits of coding" GPs described that coding is seen as being done for reimbursement purposes and is not necessarily linked to the content of their reference files for a specific patient. Others reported to code specific diagnoses only if longer consultations to explore psychosomatic symptoms or psychotherapy are intended to be billed. Reasons for b) "restrained coding" were attempting to protect the patient from stigma through certain diagnoses and the preference for tentative diagnoses and functional coding. Some GPs admitted to c) "code inaccurately" attributing this to insufficient knowledge of ICD-10-criteria, time constraints or using "rules of thumb" for coding. CONCLUSIONS: There seem to be challenges in the process of coding of MUS and somatoform disorders, but GPs appear not to contest the patients' suffering and accept uncertainty (about diagnoses) as an elementary part of their work. From GPs' points of view ICD-10-coding does not appear to be a necessary requirement for treating patients and coding might be avoided to protect the patients from stigma and other negative consequences. Our findings supply a possible explanation for the commonly seen difference between routine and epidemiological data. The recent developments in the DSM-5 and the upcoming ICD-11 will supposedly change acceptance and handling of these diagnoses for GPs and patients. Either way, consequences for GPs' diagnosing and coding behavior are not yet foreseeable.


Asunto(s)
Codificación Clínica , Médicos Generales , Síntomas sin Explicación Médica , Trastornos Somatomorfos/diagnóstico , Actitud del Personal de Salud , Femenino , Grupos Focales , Alemania , Humanos , Clasificación Internacional de Enfermedades , Masculino , Pautas de la Práctica en Medicina
12.
Science ; 360(6395): 1326-1330, 2018 Jun 22.
Artículo en Inglés | MEDLINE | ID: mdl-29930132

RESUMEN

Attosecond metrology of atoms has accessed the time scale of the most fundamental processes in quantum mechanics. Transferring the time-resolved photoelectric effect from atoms to molecules considerably increases experimental and theoretical challenges. Here we show that orientation- and energy-resolved measurements characterize the molecular stereo Wigner time delay. This observable provides direct information on the localization of the excited electron wave packet within the molecular potential. Furthermore, we demonstrate that photoelectrons resulting from the dissociative ionization process of the CO molecule are preferentially emitted from the carbon end for dissociative 2Σ states and from the center and oxygen end for the 2Π states of the molecular ion. Supported by comprehensive theoretical calculations, this work constitutes a complete spatially and temporally resolved reconstruction of the molecular photoelectric effect.

13.
Aliment Pharmacol Ther ; 48(3): 313-321, 2018 08.
Artículo en Inglés | MEDLINE | ID: mdl-29863286

RESUMEN

BACKGROUND: Minimal hepatic encephalopathy (HE) and HE grade 1 (HE1) according to the West Haven criteria have recently been grouped as one entity named-covert HE- (CHE). Data regarding the impact of CHE on health-related quality of life (HRQoL) and sleep quality are controversial. AIM: First, to determine whether CHE affects HRQoL and sleep quality of cirrhotic patients and second, whether minimal HE (MHE) and HE1 affect HRQoL and sleep quality to a comparable extent. METHODS: A total of 145 consecutive cirrhotic patients were enrolled. HE1 was diagnosed clinically according to the West Haven criteria. Critical flicker frequency and the Psychometric Hepatic Encephalopathy Score were used to detect MHE. Chronic Liver Disease Questionnaire (CLDQ) was used to assess HRQoL and Pittsburgh Sleep Quality Index (PSQI) was applied to assess sleep quality. RESULTS: Covert HE was detected in 59 (40.7%) patients (MHE: n = 40; HE1: n = 19). Multivariate analysis identified CHE (P < 0.001) and female gender (P = 0.006) as independent predictors of reduced HRQoL (CLDQ total score). CHE (P = 0.021), low haemoglobin (P = 0.024) and female gender (P = 0.003) were identified as independent predictors of poor sleep quality (PSQI total score). Results of CLDQ and PSQI were comparable in patients with HE1 and MHE (CLDQ: 4.6 ± 0.9 vs 4.5 ± 1.2, P = 0.907; PSQI: 11.3 ± 3.8 vs 9.9 ± 5.0, P = 0.3). CONCLUSION: Covert HE was associated with impaired HRQoL and sleep quality. MHE and HE1 affected both outcomes to a comparable extent supporting the use of CHE as a clinically useful term for patients with both entities of HE in clinical practice.


Asunto(s)
Encefalopatía Hepática/complicaciones , Encefalopatía Hepática/fisiopatología , Cirrosis Hepática/complicaciones , Cirrosis Hepática/fisiopatología , Calidad de Vida , Sueño/fisiología , Adulto , Anciano , Anciano de 80 o más Años , Estudios de Cohortes , Femenino , Encefalopatía Hepática/diagnóstico , Encefalopatía Hepática/epidemiología , Humanos , Cirrosis Hepática/epidemiología , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Psicometría , Factores de Riesgo , Trastornos del Sueño-Vigilia/diagnóstico , Trastornos del Sueño-Vigilia/epidemiología , Trastornos del Sueño-Vigilia/etiología , Encuestas y Cuestionarios
14.
Clin Exp Immunol ; 193(2): 207-220, 2018 08.
Artículo en Inglés | MEDLINE | ID: mdl-29645082

RESUMEN

Paediatric asthma exacerbations are often caused by rhinovirus (RV). Moreover, 25(OH)-vitamin D3 (VitD3) deficiency during infancy was found associated with asthma. Here, we investigated the innate immune responses to RV and their possible modulation by 25(OH)-VitD3 serum levels in a preschool cohort of children with and without asthma. The innate lymphoid cell type 2 (ILC2)-associated marker, ST2, was found up-regulated in the blood cells of asthmatic children with low serum levels of 25(OH)-VitD3 in the absence of RV in their airways. Furthermore, in blood cells from control and asthmatic children with RV in their airways, soluble (s) ST2 (sST2) protein was found reduced. Asthmatic children with low 25(OH)-VitD3 in serum and with RV in vivo in their airways at the time of the analysis had the lowest sST2 protein levels in the peripheral blood compared to control children without RV and high levels of 25(OH)-VitD3. Amphiregulin (AREG), another ILC2-associated marker, was found induced in the control children with RV in their airways and low serum levels of 25(OH)-VitD3. In conclusion, the anti-inflammatory soluble form of ST2, also known as sST2, in serum correlated directly with interleukin (IL)-33 in the airways of asthmatic children. Furthermore, RV colonization in the airways and low serum levels of 25(OH)-VitD3 were found to be associated with down-regulation of sST2 in serum in paediatric asthma. These data indicate a counter-regulatory role of 25(OH)-VitD3 on RV-induced down-regulation of serum sST2 in paediatric asthma, which is relevant for the therapy of this disease.


Asunto(s)
Asma/inmunología , Colecalciferol/sangre , Resfriado Común/inmunología , Proteína 1 Similar al Receptor de Interleucina-1/metabolismo , Leucocitos Mononucleares/fisiología , Sistema Respiratorio/metabolismo , Rhinovirus/inmunología , Células Cultivadas , Niño , Preescolar , Estudios de Cohortes , Progresión de la Enfermedad , Femenino , Humanos , Inmunidad Innata , Proteína 1 Similar al Receptor de Interleucina-1/genética , Interleucina-33/metabolismo , Leucocitos Mononucleares/virología , Masculino , Regulación hacia Arriba
15.
Pneumologie ; 72(4): 309-312, 2018 Apr.
Artículo en Alemán | MEDLINE | ID: mdl-28841740

RESUMEN

Hernia of Morgagni is the most rare of the four types of congenital diaphragmatic hernia (2 % - 3 % of all cases). In adults, it commonly presents with non-specific symptoms. In severe cases patients complain about shortness of breath and in lung function analysis a restrictive pattern can be observed. This paper presents a rare case of a massive diaphragmatic hernia of the right thorax which remained undiagnosed over many years and gives an up-to-date overview of the literature. The transabdominal approach using laparoscopic repair is favored in adults especially in non-acute cases. In our patient, the lung expanded postoperatively in most parts resulting in improvement of lung function and blood gas analysis.


Asunto(s)
Hernia Diafragmática/cirugía , Herniorrafia/métodos , Laparoscopía/métodos , Pulmón/fisiopatología , Adulto , Análisis de los Gases de la Sangre , Hernia Diafragmática/diagnóstico , Hernias Diafragmáticas Congénitas , Humanos , Resultado del Tratamiento
16.
Toxicol Lett ; 293: 264-268, 2018 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-28964811

RESUMEN

Reactive Skin Decontamination Lotion (RSDL®) is used for the decontamination of Chemical Warfare Agents and Toxic Industrial Compounds after dermal exposure. It has to be stockpiled over a long period and is handled in all climatic zones. Therefore stability is an essential matter of concern. In this work we describe a study to the chemical stability of RSDL® as basis for an estimation of shelf life. We analysed RSDL® for the active ingredient 2,3-butandione monoxime (diacetylmonooxime, DAM), the putative degradation product dimethylglyoxime (DMG) and unknown degradation products by means of a reversed phase high pressure liquid chromatography (HPLC). Calculations were done according to the Arrhenius equation. Based on the temperature dependent rate constants, the time span was calculated, until defined threshold values for DAM and DMG subject to specification and valid regulations were exceeded. The calculated data were compared to the ones gathered from stockpiled samples and samples exposed during foreign mission. The decline of DAM followed first order kinetics, while formation of DMG could be described by zero order kinetics. The rate constants were distinctively temperature dependent. Calculated data were in good accordance to the measured ones from stockpile and mission. Based on a specified acceptable DAM-content of 90% and a valid threshold value of 0.1% (w/w) for the degradation product DMG, RSDL® proved to be stable for at least four years if stored at the recommended conditions of 15°C-30°C. If continuously stored at higher temperatures shelf life will decrease markedly. Therefore RSDL® is an object for risk orientated quality monitoring during storage.


Asunto(s)
Antídotos/análisis , Descontaminación , Emulsiones/análisis , Sustancias para la Guerra Química , Cromatografía Líquida de Alta Presión , Estabilidad de Medicamentos , Almacenaje de Medicamentos , Cinética , Límite de Detección , Oximas , Reproducibilidad de los Resultados , Temperatura
17.
Eur J Intern Med ; 51: 41-45, 2018 05.
Artículo en Inglés | MEDLINE | ID: mdl-29229303

RESUMEN

BACKGROUND: Cardiovascular disease is a serious problem of liver transplant (LT) recipients because of increased cardiovascular risk due to immunosuppressive therapy, higher age, intraoperative risk and comorbidities (such as diabetes and nicotine abuse). Reported frequency of cardiovascular events after LT shows a high variability between different LT cohorts. Our aim was to analyze a cohort of LT recipients from a single center in Germany to evaluate frequency of the cardiovascular endpoints (CVE) myocardial infarction and/or cardiac death after LT and to investigate correlations of CVE post LT with pretransplant patient characteristics. PATIENTS: In total, data from 352 LT patients were analyzed. Patients were identified from an administrative transplant database, and all data were retrieved from patients' charts and reports. RESULTS: During the median follow-up of 4.0 (0-13) years, 10 cases of CVE were documented (six myocardial infarctions and four coronary deaths). The frequency of CVE did not differ according to classic cardiovascular risk factors such as body mass index (p=0.071), total cholesterol (p=0.533), hypertension (p=0.747), smoking (p=1.000) and pretransplant diabetes mellitus (p=0.146). In patients with pretransplant coronary heart disease (n=24; 6.8%) CVE were found more frequently (p=0.024). CONCLUSION: In summary, we found a rate of 2.8% CVE after LT in a German transplant cohort. Pretransplant CHD was the only risk factor for CVE, but showed no significant impact on overall survival.


Asunto(s)
Enfermedad Coronaria/epidemiología , Muerte Súbita Cardíaca/epidemiología , Trasplante de Hígado/efectos adversos , Trasplante de Hígado/mortalidad , Infarto del Miocardio/epidemiología , Adulto , Enfermedad Coronaria/complicaciones , Bases de Datos Factuales , Muerte Súbita Cardíaca/etiología , Femenino , Alemania/epidemiología , Humanos , Hipertensión/complicaciones , Masculino , Persona de Mediana Edad , Infarto del Miocardio/etiología , Complicaciones Posoperatorias , Factores de Riesgo
18.
Atheroscler Suppl ; 30: 50-55, 2017 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-29096861

RESUMEN

BACKGROUND: In recent years the Federal Joint Committee (G-BA), a paramount decision-making body of the German health care system required a reassessment of the approval of chronic lipoprotein apheresis therapy for regular reimbursement. Since 2005 an interdisciplinary German apheresis working group has been established by members of both German Societies of Nephrology. In 2009 the working group completed the indication for lipoprotein apheresis with respect to current cardiovascular guidelines and current scientific knowledge for the registry. In 2011 the German Lipoprotein Apheresis Registry (GLAR) was launched and data acquired over nearly 5 years can now be reported. METHODS AND RESULTS: All data were collected and analyzed during the time period 2012-2015. Over this time interval, 68 German apheresis centers collected retrospective and prospective observational data of 1.283 patients undergoing lipoprotein apheresis (LA) treatment of high LDL-cholesterol (LDL-C) levels and/or high lipoprotein(a) (Lp(a)) levels suffering from progressive cardiovascular disease (CVD). A total of 15,167 documented LA treatments were investigated. All patients treated by LA exhibited a median LDL-C reduction rate of 68.6%, and a median Lp(a) reduction rate of 70.4%. Analogue to the Pro(a)LiFe pattern, patient data were analyzed and compared with respect to the incidence rate of coronary events (MACE) 1 and 2 years before the start of LA treatment (y-2 and y-1) and prospectively one year on LA treatment (y+1). During the first year of LA treatment a MACE reduction of 97% was be observed. In the years considered, LA treatment side effects occurred at a low rate (ca. 5%) and mainly comprised puncture problems. CONCLUSIONS: For the first time data generated by the GLAR shows that LA lowers the incidence rate of cardiovascular events in patients with high LDL-C and/or high Lp(a) levels, progressive CVD and maximally tolerated lipid lowering medication. In addition LA treatments were found to be safe, exhibiting a low rate of side effects.


Asunto(s)
Eliminación de Componentes Sanguíneos/métodos , Enfermedades Cardiovasculares/prevención & control , LDL-Colesterol/sangre , Hipercolesterolemia/terapia , Lipoproteína(a)/sangre , Sistema de Registros , Adulto , Anciano , Anciano de 80 o más Años , Biomarcadores/sangre , Eliminación de Componentes Sanguíneos/efectos adversos , Enfermedades Cardiovasculares/etiología , Femenino , Alemania , Humanos , Hipercolesterolemia/sangre , Hipercolesterolemia/complicaciones , Masculino , Persona de Mediana Edad , Evaluación de Programas y Proyectos de Salud , Proyectos de Investigación , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento , Adulto Joven
19.
Anal Bioanal Chem ; 409(23): 5463-5480, 2017 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-28674822

RESUMEN

A novel, fast and reliable sample preparation procedure for the simultaneous separation of Sr, Pb, and Nd has been developed for subsequent isotope ratio analysis of sediment digests. The method applying a fully automated, low-pressure chromatographic system separates all three analytes in a single-stage extraction step using self-packed columns filled with DGA Resin. The fully automated set-up allows the unattended processing of three isotopic systems from one sediment digest every 2 h, offering high sample throughput of up to 12 samples per day and reducing substantially laboratory manpower as compared to conventional manual methods. The developed separation method was validated using the marine sediment GBW-07313 as matrix-matched certified reference material and combines quantitative recoveries (>90% for Sr, >93% for Pb, and >91% for Nd) with low procedural blank levels following the sample separation (0.07 µg L-1 Sr, 0.03 µg L-1 Pb, and 0.57 µg L-1 Nd). The average δ values for Sr, Pb, and Nd of the separated reference standards were within the certified ranges (δ (87Sr/86Sr)NIST SRM 987 of -0.05(28) ‰, δ(208Pb/206Pb)NIST SRM 981 of -0.21(14) ‰, and δ(143Nd/144Nd)JNdi-1 of 0.00(7) ‰). The DGA Resin proved to be reusable for the separation of >10 sediment digests with no significant carry-over or memory effects, as well as no significant on-column fractionation of Sr, Pb, and Nd isotope ratios. Additional spike experiments of NIST SRM 987 with Pb, NIST SRM 981 with Sr, and JNdi-1 with Ce revealed no significant impact on the measured isotopic ratios, caused by potential small analyte peak overlaps during the separation of Sr and Pb, as well as Ce and Nd.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...